The cart is empty.
Your Trusted Partner for Expert Security Solutions.
DWG

1430118 Potter 3000-203 4 Square Electrical Back Box Cover Plate

SKU: 1430118

F3000 Series

End-to-End Infrared Optical Beam Smoke Detector

The F3000 End to End infrared Optical Beam Smoke Detector (OBSD) has been designed using the latest optical technology, incorporating modern industrial, electronic and software techniques.This detector offers cost effective protection of large, open area spaces with high ceilings. It is also very suited to applications where access to ceiling mounted smoke detectors presents practical difficulties.

The F3000 is ideal for applications where line of sight for the IR (infra-red) detection path is narrow and where the building structure uses reflective surfaces. It has also been designed to be aesthetically pleasing and thus can equally suit modern architectural buildings as well as historical sites, particularly where ornate ceilings exist.

More details...
MPN: 1430118
MSRP Price: $95.00
Price: $95.00
Save to my Wish List

New to DWG? - Sign Up for immediate access to dealer pricing and benefits.

Already a DWG Customer? - Sign In to view pricing.



Product Details

Features

  • Separate Transmitter and Receiver Heads
  • Range 16.5 to 393 feet. Configurable per set of Detectors
  • Lateral Spacing per NFPA 72 is 60 feet
  • Integral Laser Alignment in Receiver
  • 2-wire Interface between Controller and Receiver
  • Single and Twin Channel capability
  • Separate Fire and Fault Relays per Detector
  • Low Level Controller with LCD display
  • Programmable Sensitivity and Fire Threshold
  • Automatic Gain Control (AGC) for drift compensation
  • Built-in electronics UL/ULC obstruction-acceptance fire test
  • Knockouts for ease of installation and wiring
  • Optional Transmitter powering from Controller

Description

The Fireray 3000 End to End Infra-red Optical Beam Smoke Detector (OBSD) has been designed using the latest optical technology, incorporating modern industrial, electronic and software techniques. This detector offers cost effective protection of large, open area spaces with high ceilings. It is also very suited to applications where access to ceiling mounted smoke detectors presents practical difficulties

The Fireray 3000 is ideal for applications where line of sight for the IR (infra-red) detection path is narrow and where the building structure uses reflective surfaces. Ithas also been designed to be aesthetically pleasing and thus can equally suit modern architectural buildings as well as historical sites, particularly where ornate ceilings exist.

Engineering Specification

The projected beam type smoke detector shall be listed to U.L. 268 and shall consist of up to two transmitters, two receivers and a single low level remote control unit. The detector shall operate between a range of 16.5 ft. to 393 ft. (5m to I 20m). The temperature range of the system shall be -4°F to 131°F (-20°C to 55°C). The receiver shall indude an integral built-in laser pointer to assist in optimum alignment.

The beam detector shall feature automatic gain control, which will compensate for gradual signal deterioration from dirt accumulation on the lenses. The receiver heads shall incorporate a Wide Held of View to ensure the unit is always receiving maximum signal available. The system shall indude a low level remote display and control unit with LCD read-out for set-up, reporting and testing of up to 2 separate sets of heads. The system shall be capable of sending separate Trouble and Alarm signals for each of the sets of heads. The system shall be capable of programming alarm thresholds of 25% to 60% in 1% increments. The system shall be capable of programming delay to fault and delay to alarm from 2 seconds to 30 seconds in I second increments.

Test and acceptance of the system shall be carried out by using the UL/ ULC approved internal electronic obscuration fire test. The projected beam type smoke detector shall be a 4-wire 24VDC device to be used with a Nationally Recognized Testing Laboratory's Listed and separately supplied 4- wire control panel. The End to End beam type smoke detector shall be a FFE Ltd. fireray 3000.

Technical Specifications

  • Operating Range: - 16.5 ft 393 ft (5 to 120m)
  • Operating Voltage Range: - 12 to 36V DC ±10%
  • Operating Controller Current (with 1 or 2 Receivers): - 14mA (constant)
  • Operating Transmitter Current: - 8mA (per Transmitter)
  • Power Down Reset Time: - >20 seconds
  • Fire and Fault Relay Contacts: - Resistive VFCO 2A @ 30 Volts DC
  • Operating Temp. (non-condensing): UL - -4°F to +131°F (-20°C to +55°C)
  • Optical Wavelength: - 850nm
  • LED Indications: Control Unit - Red = Fire, Amber = Fault, Green = System OK, Alignment LEDs for single person alignment Receiver
  • IP Rating: - IP54
  • Relative Humidity (non-condensing): - 93%
  • Parts List (System) - 1 x Transmitter (clear lens), 1 x Receiver (dark lens), 1 x Control Unit, 1 x Transmitter (clear lens), 1 x Receiver (dark lens), Parts List (Additional Detector):
  • Housing Material (Transmitter/Receiver/Controller): - UL94 V2 PC
  • Cabling between each Receiver and Controller: - 18-14 AWG 1-Pair Twisted, Jacketed
  • Maximum Cable Distance between Receiver & Controller: - 330 Feet (100m)