The cart is empty.
Your Trusted Partner for Expert Security Solutions.
DWG

1430166 Potter 3000-209 F-3000 Controller Surface/Semiflush Mount Back Box

SKU: 1430166

FR3000 EXD Series

Explosion Proof Flame Proof Optical Beam Smoke Detector

The FR3000 Exd is ideally suited for the protection of large areas, with potentially explosive atmospheres, against smoking fires. FR3000 Exd comprises an infrared transmitter and a receiver, both of which are ATEX-certified for use in Class 1 Div 1 Group 2 hazardous areas. There is a separate, safe area, wall-mounted remote/low level control unit to allow adjustment and testing from a convenient non-hazardous location.

The product is designed for large enclosures within oil rigs, refineries, ordnance stores and similar premises. It provides an early warning of smouldering or strongly smoke-generative fires, which may not be picked up by flame detectors installed in many hazardous areas.

More details...
MPN: 1430166
Ordering Notes: Service Professionals Only
MSRP Price: $128.00
Price: $128.00
Save to my Wish List

New to DWG? - Sign Up for immediate access to dealer pricing and benefits.

Already a DWG Customer? - Sign In to view pricing.



Product Details

Features

  • Separate transmitter and receiver unit certified to Exd
  • Allows for 2 Detectors per System Controller
  • Range 33ft to 262ft, (10 to 80 metres) configurable per set of Detectors
  • Integral Laser Alignment in Receiver
  • 2-wire Interface between Controller and Receiver
  • Separate Alarm and Trouble Relays per Detector
  • Remote/low Level Controller with LCD display (Safe Area)
  • Programmable Sensitivity and Fire/Fault delay
  • Automatic Gain Control (AGC) for drift compensation
  • First Fix concept for transmitter, reciever and controller
  • Multiple cable gland knockouts for ease of wiring
  • Transmitter can be powered from Controller
  • Complies with ATEX
  • Light Cancellation Technology

Description

The Fireray 3000 Exd is ideally suited for the protection of large areas, with potentially explosive atmospheres, against smoking fires. Fireray 3000 Exd comprises an infrared transmitter and a receiver, both of which are ATEX-certified for use in Group 2 hazardous areas. There is a separate, safe area, wall-mounted remote/low level control unit to allow adjustment and testing from a convenient non-hazardous location.

The product is designed for large enclosures within oil rigs, refineries, ordnance stores and similar premises. It provides an early warning of smouldering or strongly smoke-generative fires, which may not be picked up by flame detectors installed in many hazardous areas.

Operation

The Transmitter head emits a narrow beam of infra-red light to an associated Receiver head. Once smoke crosses through and thus obscures the IR beam path, the signal strength at the Receiver drops below a preset level which in turn results in an alarm condition.

The Fireray 3000 Exd has been designed so that it can be installed by one operator, with its laser assisted alignment method combined with easy to use alignment LEDs offering visual feedback. Integrated laser alignment aid can be activated at the Controller.

The Fireray 3000 Exd also has a feature which allows for the Transmitter to be powered from the Controller by wiring directly, thus reducing the number of power supplies required.

The low level system Controller incorporates a LCD display, which offers a full icon-based, easy-to-use interface unit. This Controller enables ease of commissioning, testing and maintenance of the beam detection system. During commissioning the detector’s fire sensitivity thresholds can be selected, along with the user variable time to alarm and time to trouble settings. The system is fully compliant with the requirements of RoHS and WEEE.

Technical Specifications

  • Operating Range: - 33ft to 262ft, (10 to 80 metres)
  • Operating Voltage Range: - 12 to 36V DC ±10%
  • Operating Controller Current (with 1 or 2 Receivers): - 14mA (constant)
  • Operating Transmitter Current: - 8mA (per Transmitter)
  • Power Down Reset Time: - >20 seconds
  • Fire and Fault Relay Contacts: - VFCO 2A @ 30 Volts DC resistive
  • Operating Temp. (non-condensing): - -10°C to +55°C, (14°f to131°f)
  • Optical Wavelength: - 850nm

LED Indications

  • Control Unit - Red = Fire, Amber = Fault, Green = System OK
  • Receiver - Alignment LEDs for single person alignment
  • IP Rating - IP54 (Controller) IP66 (Transmitter/Receiver)
  • Relative Humidity (non-condensing): - 93%
  • Parts List (System):
    • 1 x Transmitter (clear lens)
    • 1 x Receiver (dark lens)
    • 1 x Control Unit
    • 1 x Fixing Kit
    • 2 x Brackets
  • Parts List (Additional Detector):
    • 1 x Transmitter (clear lens)
    • 1 x Receiver (dark lens)
    • 1 x Fixing Kit
    • 2 x Brackets

Housing Material

  • (Controller): - UL94 V2 PC
  • Transmitter/Receiver): - Copper Free Aluminum Alloy LM25, red
  • Cable Gland Entries: - 3 x 20mm
  • ATEX Approval - SIRA 15ATEX1260

Weight

  • Control Unit - 21.37602oz (606g)
  • Transmitter & Receiver (Inc. Brackets): - 8lb 2.513670oz (3.7kg)